Stand de testare la anduranță a pompelor de combustibil
Continental Powertrain - Brasov
Durability tester for automotive fuel pumps. The system is realised according to ATEX standards and is composed of:
- inertized enclosure (for devices under test – up to 6 units);
- hydraulic circuits (6 pcs.) reproducing various configurations of the on-board fuel circuit;
- rack with control and measuring equipment.
The inertized enclosure and the hydraulic circuit are installed inside a ventilated chamber for fuel vapour extraction.
The hydraulic circuits simulates all normal and abnormal operating modes of the car on-board fuel system.
- inertized enclosure (for devices under test – up to 6 units);
- hydraulic circuits (6 pcs.) reproducing various configurations of the on-board fuel circuit;
- rack with control and measuring equipment.
The inertized enclosure and the hydraulic circuit are installed inside a ventilated chamber for fuel vapour extraction.
The hydraulic circuits simulates all normal and abnormal operating modes of the car on-board fuel system.
The test is performed automatically – no operator intervention required during test. Test duration up to 10000 hours.
Industrial software
We provide industrial data acquisition and control software, custom made for customer's needs
MoreDesign and engineering
Our company provides turn-key solutions, including design of complex industrial equipment ...
MoreATEX authorization
Our company is certified by INSEMEX for engineering, installation, maintenance and inspection of Ex area installations ...